Fast recovery diode JUXING MUR3040PT suitable for high frequency inverter and surge current circuits
Product Overview
The MUR3040PT/PTS are ultrafast recovery rectifiers designed for high-speed switching applications. They offer high current and forward surge capabilities, leading to low power losses and high efficiency. These rectifiers are suitable for use in low voltage, high frequency inverters and fast recovery diode applications, particularly in high-equipment, express, and ultrafast circuits.
Product Attributes
- Case: Molded plastic
- Polarity: As marked
- Mounting Position: Any
- Molded Plastic: UL Flammability Classification Rating 94V-0
- Lead free in compliance with EU RoHS 2011/65/EU directive
- Assembly code: CR
- Solder bath temperature: 275C maximum, 10s per JESD 22-
Technical Specifications
| Characteristics | Symbol | Value | Unit | Notes |
| Maximum Repetitive Peak Reverse Voltage | VRRM | 400 | V | |
| Working Peak Reverse Voltage | VRWM | 400 | V | |
| Maximum DC Blocking Voltage | VDC | 400 | V | |
| Maximum Average Forward Rectified Current (Per Leg) | IO | 15 | A | Total 30A |
| Peak Forward Surge Current, 8.3 ms Single Half Sine-wave | IFSM | 320 | A | Superimposed on Rated Load (JEDEC method) |
| Operating Temperature Range | TJ | 150 | C | |
| Storage Temperature Range | TSTG | -40 to +150 | C | |
| Typical Thermal Resistance (Junction to Case per leg) | RJC | 2 | C/W | Mounted on heatsink. |
| Forward Voltage Drop (Typ.) at IF=3A | VF | 0.84 | V | TA=25C |
| Forward Voltage Drop (Max.) at IF=3A | VF | - | V | TA=25C |
| Forward Voltage Drop (Typ.) at IF=3A | VF | 0.68 | V | TA=125C |
| Forward Voltage Drop (Max.) at IF=3A | VF | - | V | TA=125C |
| Forward Voltage Drop (Typ.) at IF=5A | VF | 0.90 | V | TA=25C |
| Forward Voltage Drop (Max.) at IF=5A | VF | - | V | TA=25C |
| Forward Voltage Drop (Typ.) at IF=5A | VF | 0.74 | V | TA=125C |
| Forward Voltage Drop (Max.) at IF=5A | VF | - | V | TA=125C |
| Forward Voltage Drop (Typ.) at IF=15A | VF | 1.06 | V | TA=25C |
| Forward Voltage Drop (Max.) at IF=15A | VF | 1.39 | V | TA=25C |
| Forward Voltage Drop (Typ.) at IF=15A | VF | 0.90 | V | TA=125C |
| Forward Voltage Drop (Max.) at IF=15A | VF | - | V | TA=125C |
| Maximum Reverse Current at VR=400V (TA=25C) | IR | 0.10 | A | |
| Maximum Reverse Current at VR=400V (TA=125C) | IR | 10.00 | A | |
| Maximum Reverse Recovery Time at IF=0.5A, IR=1A | Trr | 35.00 | ns |