Littelfuse IXYS DPF240X400NA Fast Recovery Diode with parallel legs and low EMI RFI characteristics

Key Attributes
Model Number: DPF240X400NA
Product Custom Attributes
Reverse Leakage Current (Ir):
10uA@400V
Reverse Recovery Time (trr):
30ns
Operating Junction Temperature Range:
-40℃~+150℃
Voltage - DC Reverse (Vr) (Max):
400V
Diode Configuration:
2 Independent
Voltage - Forward(Vf@If):
1.25V@120A
Current - Rectified:
120A
Mfr. Part #:
DPF240X400NA
Package:
SOT-227B
Product Description

Product Overview

The DPF240X400NA is a high-performance Fast Recovery Diode featuring low loss and soft recovery characteristics. Designed with parallel legs and planar passivated chips, this diode offers very low leakage current, very short recovery time, and improved thermal behavior. Its very low Irm-values and soft reverse recovery contribute to reduced power dissipation and lower turn-on losses in commutating switches, making it ideal for applications requiring low EMI/RFI. Key applications include antiparallel diodes for high-frequency switching devices, antisaturation diodes, snubber diodes, free-wheeling diodes, and rectifiers in switch mode power supplies (SMPS) and uninterruptible power supplies (UPS).

Product Attributes

  • Brand: IXYS
  • Part Number: DPF240X400NA
  • Package: SOT-227B (minibloc)
  • Certifications: Epoxy meets UL 94V-0
  • RoHS Compliant
  • Base plate: Copper internally DCB isolated

Technical Specifications

Symbol Definition Conditions Unit typ. max. min.
VRRM max. repetitive reverse blocking voltage Tj = 25C V 400
VRRM max. repetitive reverse blocking voltage Tj = 150C V 400
VRSM max. non-repetitive reverse blocking voltage Tj = 25C V 400
IF(AV) average forward current Tc = 125C A 2x 120
IF(AV) average forward current Tc = 150C A 2x 120
IFSM max. forward surge current t = 10 ms; (50 Hz), sine; Tj = 45C kA 1.20
IFSM max. forward surge current t = 10 ms; (50 Hz), sine; Tj = 150C kA 1.01
VF forward voltage drop IF = 240 A; Tj = 25C V 1.54
VF forward voltage drop IF = 240 A; Tj = 150C V 1.42
VF0 threshold voltage Tj = 25C V 0.71
rF slope resistance for power loss calculation only Tj = 25C m 2.9
rF slope resistance for power loss calculation only Tj = 150C m 1.06
IR reverse current, drain current VR = 400 V; Tj = 25C mA 0.5
IR reverse current, drain current VR = 400 V; Tj = 150C mA 150
Ptot total power dissipation Tc = 25C W 250
RthJC thermal resistance junction to case K/W 0.5
RthCH thermal resistance case to heatsink K/W 0.1
CJ junction capacitance VR = 200 V; f = 1 MHz pF 187
trr reverse recovery time IF = 120 A; -diF/dt = 200 A/s; VR = 240 V; Tj = 125C ns 18 30
IRM max. reverse recovery current IF = 120 A; -diF/dt = 200 A/s; VR = 240 V; Tj = 125C A 140
Qrr reverse recovery charge IF = 120 A; -diF/dt = 200 A/s; VR = 240 V; Tj = 125C C 30
Erec recovery energy IF = 120 A; -diF/dt = 200 A/s; VR = 240 V; Tj = 125C J 100
Isolation Voltage t = 1 second V~ 3000
Tj virtual junction temperature C 150 -40
Tstg storage temperature C 150 -40
Mounting torque Nm 1.5 1.1
Terminal torque Nm 1.5 1.1
Weight g 30